3150 Fleck Valve for Water Treatment System

Product Details
Customization: Available
Type: Reverse Osmosis
Usage: Environmental Protection
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (18)
  • 3150 Fleck Valve for Water Treatment System
  • 3150 Fleck Valve for Water Treatment System
Find Similar Products

Basic Info.

Model NO.
3150
Style
Vertical
Performance
Sophisticated Filters
Certification
CE, RoHS, EMC, SASO
Transport Package
Cartons
Specification
3150
Trademark
PENTAIR
Origin
China
HS Code
8421
Production Capacity
5000PCS Per Month

Product Description

Model: FLECK 3150
 1. Fully adjustable, 5-cycle control is efficient and reliable, delivering controlled upflow backwash, down flow brining and down flow service
2. Versatile top or side mount is suitable for commercial or industrial applications
3. Backwash capacity accommodates tanks up to 63" diameter
4. Solid, lead-free brass construction for superior strength and durability
5. Protective NEMA 3R equivalent enclosure is rain tight, and UV stable
6. Flexible 7 or 12 day time clock or meter initiated regeneration
7. Ideal for most filter applications up to 42"
Name: Fleck 3150 2" Commercial Control Valve
Features:
1.     Fully adjustable, 5-cycle control is efficient and reliable, delivering controlled up-flow backwash, down-flow brining and down-flow service 
2.Versatile top or side mount is suitable for commercial or industrial applications
3.Backwash capacity accommodates tanks up to 60" diameter
4.Solid, lead-free brass construction for superior strength and durability
5.Protective NEMA 3R equivalent enclosure is rain tight, and UV stable
6.Flexible 7 or 12 day time clock or meter initiated regeneration

Options
1. Backwash filter
2. Meter initiated regeneration
3. Service valve operator
4.Side mount
5.Electronic timer, 3200NT, 3214NT, or XT
6.Hot water (time clock 180°F; metered valve 150°F)
7.Treated water regeneration
8. No hard water bypass
9.Up-flow regeneration
10.Auxiliary switch
Valve Specifications

 
Valve material Nonleaded brass
Inlet/Outlet pipe diameter 2″NTPF
Regenerative process 5

Range of flow (0.35MPa Inflow pressure)
Installation methods Top-mounted Side-mounted
Continuous water inflow (0.1MPa drop) 21.59 m3/h 22.72 m3/h
Peak water inflow (0.175MPa drop) 28.18 m3/h 29.31 m3/h
Cv 24.8 25.9
Back-wash flow (0.175MPa drop) 23.85 m3/h 24.76 m3/h

Regeneration
Down/Up flow Both are suitable
Program regulation All regeneration steps can be accommodation
Maximum regenerative time Motor control:164 per cycle
ET control:0-999.9 minute
Systemax control:0-999.9 minutes

Meter
Accuracy 0.68-34.07 m3/h±5%
Capacity options Standard:4.73-80.49m3
Extended:23.67-402.46 m3
ET: 0-37852.11 m3
Systemax:0-378521.15m3

Main size
Central line diameter 2″(2.375″)O.D.
Drain line diameter 2″NPTF
Brine line diameter 1″NPTM
Base diameter Top-mounted:4″-8UN
Height from top of tank 10″
Suited base diameter Soften:24″- 63″
Expect filter:24″-42″

Additional Information
Regenerative system 1″-1800
Electrical rating 24V,110V,220V-50,60Hz
Maximum power 87W
Estimated shipping weight Time clock:39 Ibs
Metered valve:46 Ibs
Pressure Designed:2.1MPa
Operating:0.14-0.84MPa
Operating Temperature 34°-110°F(10°-43°C)
* It has been proved as safe drinking water device material.
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now