Customization: | Available |
---|---|
Type: | Reverse Osmosis |
Usage: | Environmental Protection |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Valve material |
Nonleaded brass |
Inlet/Outlet pipe diameter | 1-1/2″NTPF |
Regenerative process | 5 |
Continuous water inflow (0.1MPa drop) |
Side-mounted:11.5 m3/h |
Peak water inflow (0.175MPa drop) | Side-mounted:15 m3/h |
Cv | 13.2 |
Back-wash flow (0.175MPa drop) | 11.13 m3/h |
Down/Up flow |
Only Down flow |
Program regulation | All regeneration steps can be accommodation |
Maximum regenerative time | Motor control:164 per cycle SE control: 0-99 minutes ET control:0-999.9 minute Systemax control:0-999.9 minutes |
Accuracy |
1″:0.16-9.09 m3/h±5% 1-1/2″:0.34-17.04 m3/h±5% |
Maximum regenerative time | 1″: Standard:1.17-19.06 m3 Extended:5.87-99.81 m3 1-1/2″: Standard:2.36-40.24 m3 Extended:11.83-201.23 m3 ET: 0-37852.11 m3 Systemax:0-378521.15m3 |
Central line diameter |
1.5″(1.9″)O.D. |
Drain line diameter | 1″NPTM |
Brine line diameter | 3/8″&1/2″ |
Base diameter | 4″-8UN |
Height from top of tank | 6-1/2″ |
Suited base diameter | Soften:10″- 30″ Expect filter :10″-24″ |
Regenerative system |
3/8″-1600, 3/8″-1650, 1/2″-1700 |
Electrical rating | 24V,110V,220V-50,60Hz |
Maximum power | 72W |
Estimated shipping weight | Time clock:19 Ibs Metered valve:27 Ibs |
Pressure | Designed:2.1MPa Operating:0.14-0.84MPa |
Operating temperature | 34°-110°F(10°-43°C) |
* It has been proved as safe drinking water device material. |